AC Current Transducers - Low Current


SERIES
S383L
  • AC Average responding 50 - 60 Hz
  • Accuracy +/- 250 µA from - 40°C to +85°C
  • Detect less than 50 mA with multiple turns; 10 turns detects 0 to 5 mA
  • Other frequencies available upon request

 

Range
50 mA to 1 amp

SERIES
1055L
  • AC Average responding 50 - 60 Hz
  • Accuracy +/- 250 µA from - 20°C to +85°C
  • Detect less than 50 mA with multiple turns; 10 turns detects 0 to 5 mA
  • Other frequencies available upon request

Range
50mA to 1A

View 3D PDF
SERIES
1002M1
  • Average responding unit
  • Accuracy +/- 225 µA at - 55°C 
  • Accuracy +/- 200 µA at +85°C
  • Frequency of 375 to 425 Hz; other frequencies available upon request
  • 0 to 5VDC output; other voltage values available upon request

Range
250mA to 250A

View 3D PDF
SERIES
S402
  • AC RMS responding  
  • 0.38" (9mm) dia. aperture
  • Output 0 to +5 VDC
  • Shock & Vibration
  • Rated to 60,000 ft altitude

Range
250mA to 250A

View 3D PDF
SERIES
1070
  • AC RMS responding
  • 0.75" (19mm) dia. aperture
  • Output 4 to 20 mA  
  • Shock & Vibration
  • Application specific units available


  • Application News
    Range
    2A to 250A

    View 3D PDF
    SERIES
    C
    • Average responding unit
    • Low burden of 0.5VA maximum 
    • Frequency range of 47 to 1000 Hz; Standard is 60 Hz 
    • 0 to 1mA output standard; 0 to 10 VDC output options available
    • No power supply required

    Range
    1A to 20A

    View 3D PDF
    SERIES
    CX
    • Average responding unit
    • Low burden of 0.5VA maximum
    • Frequency range of 47 to 1000 Hz; Standard is 60 Hz
    • 4 to 20mA output; for DC voltage output see C series

    Range
    1A to 20A

    Please click to submit request for quote with P/N and quantity.

    Please click to submit customization request if this does not meet your requirements.


     
      570 Smith Street Farmingdale, NY 11735 | Toll Free [US] : +1 888.873.8559 | Tel : +1  631.694.5100 | Fax : +1 631.694.6739 | |  Email: info@a-a-c.com  
     