DC Current
Detectors
eight models in order of
current range
|
|
||
|
|
series
901B
|
ground fault;
output solid-state-switch and 0 to 5Vdc; accuracy 1%FS; power +21 to
+27Vdc; response 50m-sec; temperature –20° to +70°C; aperture 3/4 inch dia;
metal case; solder, connector or barrier terminations |
dc
0 to +20mA
0 to +500mA 0 to +50mA 0 to +1A 0 to +100mA 0 to +2A 0 to +
250mA
0 to +5A |
|
|
|
series
S204
|
industrial grade;
output spdt relay; accuracy 4% of set point; power +22.8 to +30.4Vdc;
response 3m-sec; temp. –20° to +70°C; aperture 3/8 inch dia; metal case;
solder, connector or barrier terminations |
dc
0 to +100mA 0 to +1.2A 0 to +150mA 0 to +2A 0 to +350mA 0 to +3A
0
to +550mA
0 to +5.75A |
|
|
|
series
S58
|
industrial grade; output
solid-state-switch; automatic reset; power +22.8 to +30.4Vdc; response
1m-sec; temperature 0° to +70°C; aperture 3/8 inch dia; metal case;
barrier screw terminations
|
dc
0 to +15Adc
switch trips @
60mAdc ±20% |
|
|
|
series
S754
|
rail transit; output solid-state-relay;
pushbutton reset; response 100m-sec; power +25 to +45Vdc; temperature -40°
to +50°C; aperture 3/4 inch dia; plastic case; barrier screw terminations
|
dc
0 to +20Adc
adjustable trip
current
500mA to 1Adc |
|
|
|
series
S201
|
aircraft do-160;
output spst relay; automatic reset; power +24 to +32Vdc; response
200m-sec; temp. –55° to +70°C; aperture 3/8 inch
dia; metal case; connector terminations; DO-160 environmental requirements
|
dc
0 to +100Adc
relay trips@
+1Adc ±15% |
|
|
|
series
S680
|
rail transit; output solid-state-relay; automatic reset;
power +25 to +45Vdc; response 1m-sec; temperature -25° to +75°C; aperture
1+1/2 inch dia; available with bus-bar; plastic case; barrier screw
terminations
|
dc
0 to +1000Adc
relay trips@
±3Adc ±10% |
|
|
|
series
S629
|
rail transit; output spst relay (10A
contacts); automatic reset; response 50m-sec; temp –25° to +75°C; power
+25 to +45Vdc; aperture 1+1/2 inch dia; bus-bar available; plastic case;
barrier screw terminations
|
dc
0 to +1000Adc
relay trips@
±45Adc ±0.5Adc |
|
|
|
series
S623
|
rail transit ground fault; output spst relay; automatic
reset; response 50m-sec; power +25 to +45Vdc; temp –25° to +75°C; aperture
1+1/2 inch dia; dual bus-bar available; plastic case; barrier screw
terminations
|
dc
0 to +1600Adc
relay trip
|
|